Coke (metallurgical) · Size & tolerance table

Metallurgical coke quality parameters and test methods

Standard: ISO 18894 · ISO 556 · ISO 728 · ASTM D5341 · ASTM D3402

The values below are typical ranges seen in contracts and plant specifications, not limits from a standard. Each blast furnace sets its own targets, and premium furnaces with high coal injection need coke at the strong end of every range.

Chemistry is given on a dry basis. Strength indices depend on the test method, so a contract should name it — an M40 by ISO 556 and a stability index by ASTM D3402 are different numbers.

Typical values by coke type

Parameter Unit Blast-furnace coke Foundry coke Test method
Ash (dry) % 10–13 8–10 ISO 1171 · ASTM D3174
Volatile matter (dry) % below 1.2 below 1.0 ISO 562 · ASTM D3175
Fixed carbon (dry) % 85–89 88–91 by difference
Total sulphur (dry) % 0.5–0.8 below 0.7 ISO 19579 · ASTM D4239
Phosphorus (dry) % below 0.03 below 0.03 ISO 622
Total moisture (as delivered) % 1–6 (dry-quenched below 1) below 5 ISO 579
M40 (drum strength) % above 80 above 80 ISO 556
M10 (abrasion) % below 7 below 8 ISO 556
Stability index % above 55 – ASTM D3402
CRI (reactivity) % 20–30 – ISO 18894 · ASTM D5341
CSR (strength after reaction) % 60–70 – ISO 18894 · ASTM D5341
Size range mm 25/30–80 above 80–100 ISO 728 · ASTM D293
Mean size mm 45–60 100–150 ISO 728